I hope you are back in your hot tub soon enjoying the hot water and relaxation, if you require any hot tub supplies such as new hot tub filters or hot tub covers please look through The Cover Guy website I know you will be very happy with the prices, delivery, and quality of our products. May 17, 2019 Coleman Hot Tub Features. Since Coleman Lay z spa is the best of the 2 with over 1200 reviews from customers on the Amazon. We’ll dive into the details of this hot tub product. Lay-Z-Massage System. The hydromassage system is the crucial feature of Coleman Lay-Z Spa Inflatable Hot Tub that is equipped with 120 bubble jets.
- FLO, FL, FLC, FL1, PS, Blinking Lights
How Do I Reset My Hot Tub Jacuzzi
Pressure Switch or Flow Switch Failure. The codes above are all related to flow issues or the pressure switch/flow switch and are the most common error codes. These error codes can be caused for several different reasons. The main reason is water flow through the spa control system, if water is not flowing at a rate to satisfy the pressure switch, it will result in one of the error codes above. The first thing you want to do before doing anything else is shut the spa down, remove the filter and make sure all the jets are open. Then power the system back up, if the error code goes away, the problem was either a dirty filter (clean or replace) or too many jets were closed off. Other issues that can cause these error codes is debris wrapped around the pump impeller, or one of the valves is not open up all the way. The most common valve; the tee handle valve, will show that the handle is up, but in many cases the gate is still half closed, make sure that it is open all the way, you may need to dismantle the fittings to look inside. The final problem could be the pressure switch/flow switch itself. You can check the switch by performing the test below. Shut the power down, remove the two wires to the pressure switch/flow switch, find some sort of wire to join the wires, but don't do it yet. Turn the power back on, you have five seconds to join the wires together, do not join them before you turn the power on. Once this is done check ACROSS the heater element post, you should have either 110 volts or 220 volts depending on what voltage is operating the control box. If the error code goes away and you are getting the proper voltage then replace the pressure switch/flow switch. Also try it this way, Unplug the wires from the pressure switch/flow switch, turn on the pump and then jump the wires. FINAL NOTE: Most spas are equipped with pressure switches and can be found threaded into the stainless steel heater manifold. Flow switches are plumbed in line with the plumbing. You can also check the pressure switch or flow switch with a an Ohm meter. When the water is not flowing it should be OPEN, not CLOSED, if it is closed replace it.- OH, OHH, OHS, OHt, HL, HiLi, Sn2, Sn3, tS, Ht, Blinking Lights

Fill the spa if needed to ensure that the tub contains the proper water level. Water should be at least in the middle of the spa skimmer. Clean the filter inside the skimmer to ensure that no dirt is blocking water from flowing through the spa. Coleman SaluSpa Inflatable Hot Tub Spa - Green Item Specifics: Model: SaluSpa 90363E Size: 77 x 28 inches Color: Green Condition: Open box-new and unused; distressed packaging Features: Cushion spa liner Digitally controlled pump Strong resistance to puncture TriTech inflated walls Packaging Condition: Original distressed packaging This item cannot be shipped out of the United States!
Temperature Sensor Failure. The error codes above are related to a temperature sensor failure, overheat problems or a flow problem. If your spa is in fact overheating then it is caused by one of two things, either the temperature sensor is defective or the relays on the circuit board that operate the heater are stuck shut causing and over heat issue, in this case you would need to either replace or repair the circuit board. For information regarding repairs click here. If your spa is not overheating and you are getting the above error codes then a couple of things could be happening. Depending on where the temp sensor is mounted; usually in the wall of the spa in a sensor mount, you could have a flow issue. Shut the spa down, remove the filter and make sure all the jets are open. Then power the system back up, if the error code goes away, the problem was either a dirty filter (clean or replace) or too many jets were closed off. In most cases overheat issues are related to the relays on the circuit board, or the temp sensor has failed and will need to be replaced.
NOTE: Temperature sensors should be mounted in a sensor mount in the wall of the spa and not behind the shield on the heater manifold with the hi limit sensor. The temp sensor is the larger of the two silver bullets.
FINAL NOTE: Balboa M7 systems have the Temperature Sensor as well as the Hi Limit sensor installed in the heater assembly, one at each end. Both are secured with black plastic nut around the gray cable. If one of these sensors needs to be replaced BOTH should be replaced at the same time. See M7 Sensors here.
- SN, Sn1, Sn2 Sn3, HL, E1, E3, Prh, HtS, Blinking Lights
Hi Limit Sensor Failure. These error codes are similar to the ones previous, however we will be looking at these at another angle. Once again these can be caused by a flow issue. The first thing you want to do before doing anything else is shut the spa down, remove the filter and make sure all the jets are open. Then power the system back up, if the error code goes away, the problem was either a dirty filter (clean or replace) or too many jets were closed off. Other issues that can cause these error codes is debris wrapped around the pump impeller, or one of the valves is not open up all the way. The most common valve; the tee handle valve, will show that the handle is up, but in many cases the gate is still half closed, make sure that it is open all the way, you may need to dismantle the fittings to look inside. At the same time this test is being done, put your hand on the stainless steel heater manifold, it should NOT be hot, it should only be at the same temperature the water in the spa is. If it is hot you have a flow issue, or if it stays hot after the pump is shut off either the pressure switch has stuck close (see FLO error codes above) or the relays on the board have stuck shut sending continuous power to the heater. If all these test are checked and they did not solve the error code issues, then it is possible you have a defective hi limit sensor.
NOTE: The Hi Limit Sensor is located behind a shield on the stainless heater manifold and is the smaller of the two silver bullets. See picture below for reference
FINAL NOTE: Balboa M7 systems have the Temperature Sensor as well as the Hi Limit sensor installed in the heater assembly, one at each end. Both are secured with black plastic nut around the gray cable. If one of these sensors needs to be replaced BOTH should be replaced at the same time. See M7 Sensors here.
For information regarding repairsclick here If you needfurther help with troubleshootingclick here
Coleman Spas Hot Tub Error Codes


Balboa Spa Side Error Codes For more information regarding Balboa tech supportclickhere pd Power supply, unit running on battery backup OH Sensors reading 112-118° F. OHH Overheat. Spa has shut down. One sensor has detected118º F at heater. OHS Overheat. Spa has shut down. One sensor has detected110º F. Flo Improper flow or pressure switch malfunction Cool Water temp 20° below set point ICE Potential freeze condition has been detected Sn1 Hi-limit sensor malfunction Sn3 Temp sensor malfunction SnA Spa is shut down. Sensor plugged into jack Ais not working. Snb Spa is shut down. Sensor plugged into jack Bis not working. SnS Sensors out of balance. If alternating with temp,may be temporary condition. If display shows only this message (blinking)spa is shut down. HFL Substantial difference between temperature sensorsdetected. Could indicate a flow problem. LF Persistent low flow problems. (Displays on the5th occurrence of 'HFL' message with 24 hours). Heater is shut down,but other spa functions run normally. dr Inadequate water detected in heater.. dry Inadequate water detected in heater. (Displayson third occurrence of 'dr' message). Spa is shut down. Pr When spa is first actuated, it will go into PrimingMode. ILOC Interlock failure - possible pump or ozone spike. (---) Unknown water temperature. (Displays when firstpowered up after refill). Std Spa operating in Standard Mode. Ecn Spa operating in Economy Mode. SL Indicates spa is in Sleep mode SF Safety Suction, Spa is shut down. SE Spa operating in Standard-in-Economy Mode. Gecko Spa Side Error Codes FLO Pressure switch failure, switch open FLC Pressure switch failure, switch closed Prr Temp sensor failure Prh Hi-limit sensor failure HL Sensor measuring 119 degrees FrE Possible freeze condition detected Hurricane Spa Side Error Codes PS Flow or pressure switch failure SH Shorted sensor OP Open Sensor Degrees LO Temp below 60 degrees - freeze HL Temp above 118 degrees OH Spa temp exceeds acceptable limits FLO Flow problem ICE Freeze condition detected SN1 Hi-limit sensor failure SN2 Temp sensor failure Spa Quip Spa Side Error Codes err 1 (H20) Prime Failed err 3 Stuck Button err 4 No Water Sensor err 5 Overtemperature err 6 Thermal Cut Out Tripped err 7 Stuck Relay err 8 No Temperature Data 01 Stuck Button 02 No Controller Data 03 Temperature Sensor 04 Water Sensor 05 Spa Over Temperature 06 Heater Thermal Cut Out 07 Stuck Heater Relay 09 Water Prime Failed Hydro-Quip Spa Side Error Codes For more information regarding Hydro-Quip tech supportclick here C Celsius CL Current Time of Day ECdu Economy Mode Duration Econ Economy Mode Turn On F Fahrenheit Fldu Filter Cycle Duration Flon Filter Cycle Turn On FLC Pressure Switch Alarm FLO Pressure Switch Alarm FrEE Freeze Protection Alarm HL High Temperature Alarm Loc Panel / Keypad Locked PrH Temperature Sensors Alarm Prr Temperature Sensors Alarm Tu Temperature Set Celsius Tu Temperature Set Fahrenheit Jacuzzi Whirlpool Spa Side Error Codes OH Overheat Protection (Heater is deactivated, pumpslow speed is activated). COOL Spa water is more than 20° F cooler than thetemperature set point. FLO Flow Switch (heater is deactivated. Pump mayalso be deactivated). Hold Panel sensors have been pressed too many timesin a short period of time. HOT Circuit Board temperature has exceeded acceptablelimit. ICE Freeze protection. No action is necessary. ICE2 Freeze protection. No action is necessary. PnL Communication between the panel and circuit boardis faulty. ---- Watchdog' (spa is deactivated) A problem hasbeen detected. Sn1 Open sensor (heater is deactivated) or Shortedsensor (spa is deactivated). Sn3 Open or shorted sensor ( heater disabled). FLO2 Closed or shorted flow switch on system startup Dream Maker Spa Side Error Codes OH Overheat Protection (Heater is deactivated, pumpslow speed is activated). FL Spa water is more than 20° F cooler than thetemperature set point. SN Flow Switch (heater is deactivated. Pump mayalso be deactivated). F2 Panel sensors have been pressed too many timesin a short period of time. F4 Circuit Board temperature has exceeded acceptablelimit. F6 Freeze protection. No action is necessary. FC Freeze protection. No action is necessary. Sundance Spa Side Error Codes For more information regarding Sundance tech supportclick here ILOC Interlock failure - possible pump or ozone spike FLO Pressure switch malfunction Hold Panel buttons pressed to many times to quickly HOT PCB temperature above acceptable limit - airblower on ICE Potential freeze condition Pnl Communication between PCB and panel interrupted Sn1 Hi-limit sensor failure Sn3 Temp sensor failure Vita Spa Side Error Codes HiLi Water temp over acceptable limit BJ2P Pump/Blower purge - normal condition PS / FLO Insuffcient water flow through heater. FP Freeze protect-temp under acceptable condition SS=0;SS=S;LS=O;LS=S Multiple causes; open sensors, bad connectionto panel, improper voltage, etc. Brett Spa Side Error Codes For more information Regarding Brett Aqualine techsupportclick here OH Temp exceeds 118 degrees Fr Freeze condition - temp below 40 degrees FL Pressure switch failure EO Shorted temp sensor E1 Open temp sensor E2 Shorted hi-limit sensor E3 Open hi-limit sensor E4 Shorted flow switch E7 Improper electrical connection Hercules Spa Side Error Codes OH Spa temp exceeds acceptable limits FLO Flow problem ICE Freeze condition detected SN1 Hi-limit sensor failure SN2 Temp sensor failure ACC (Applied Computer Controls) CoLd Temperature in the spa heater housing is below40° F. Status of the heater element is unknown. The low speed pump orcirc pump will operate continuously until the temperature rises above45° F. OH Over heat. The spa is at a temperature above108° . Do not use spa when temperature is flashing or the OH messageis displayed. HLoH Hi Limit Over Heat. Hi limit sensor is disconnectedor shorted or the spa temperature is above 112° F. SEoP Sensor open or disconnected. Heater disabledbut the spa is operational. SESH Sensor short, nonfunctional. Heater disabledbut the spa is operational. PSoC Pressure switch open with circulating pump. PSoL Pressure switch open with low pump. PSoH Pressure switch open with high pump. ToE Time out error. Rare system error. Spa unusable. Spa Builders Spa Side Error Codes For more information regarding Spa Builders tech supportclickhere Sn1 Nonfunctional high temperature sensor. Heateris deactivated. Sn2 Nonfunctional temperature sensor. Heater is deactivated. FL1 Water flow problem, inhibited or pressure switchmalfunction. Check for proper spa water level and ensure pump is primed.Check for clogged filter. FL2 Pressure switch problem. Switch closed whilepump is deactivated. COL Cool condition. If water temperature drops 20ºFbelow set temperature, low speed pump and heater activates to bringtemperature within 15º of set temperature. ICE Freeze condition. 55ºF detected. Low speed pumpand heater will activate until spa reaches 65ºF. OH High temperature condition, has reached 110ºF.Do not enter the spa. Low speed pump (and air blower if so equipped)will activate to assist in lowering temperature.
--- = 'Watchdog'.Water temperature has reached 118ºF. Entire system is disabled. Contactqualified service technician.CTI Spa Side Error Codes For more information regarding CTI tech supportclick here th1/39 On startup indicates temperature probe problem. th2/current temperature On startup indicates temperature probe problem. th3/39 On startup indicates water temperature less than39° F. OH Overheating, water over 112° F. System will restartwhen temp. drops. hot Overheating, water over 112° F. System will restartwhen temp. drops. HL High limit switch tripped. Blue Ridge Spa Side Error Codesclick here Gatsby Spa Spa Side Error Codesclick here Imperial Spa Spa Side Error Codesclick here Swift River Spa Side Error Codesclick here Winchester Spa Error Codesclick here
Coleman Spas Hot Tub Error Codes Chart
1 flash - 3 second gap | High Limit fault |
---|---|
2 flashes - 3 second gap | Pressure/Flow switch short circuit |
3 flashes - 3 second gap | Pressure/Flow switch open circuit |
4 flashes - 3 second gap | Open circuit Sensor(s) |
Flash - 1 second on, 1 second off | Same as OH |
Flash - briefly OFF once per second | Same as Sn1 or Sn3 |
Flash - briefly ON once per second | Same as FLC |
Blinking Power Indicator Light - Hydromate | High Limit tripped or, sensor fault |
1 flash per second - onga 4352, 53, 95, etc | Pressure switch open circuit - could also be motor,or motor thermal overload |
3 flashes per second - onga 4352, 53, 95, etc | Electronic fault - sensor (most common cause) orPCB |
Green flashes - Spaquip Pulsar/2095 series | Water sensor fault - lack of water |
Red/Green alternate flashes | Temperature sensor fault, open circuit, or high limittripped - push Reset Rod |